Grey loose-fill cellulose and white loose-fill fibreglass insulation samples in side-by-side wooden trays
Attic Insulation

Cellulose vs. Fibreglass Attic Insulation

Both loose-fill materials can work well in a dry, vented attic. Compare the installed depth, weight, coverage and prep work before choosing a product.

Published

Reading time

11 min read

On this page9 sections
  1. 01Which is better for your attic?
  2. 02How the two materials are made and installed
  3. 03Compare R-value, installed depth and settling
  4. 04Read a bag chart before you compare costs
  5. 05Consider moisture, ceiling load and the eaves
  6. 06Can you add cellulose over fibreglass or the reverse?
  7. 07Address air leaks and compare the whole job
  8. 08Match the material to the attic you actually have
  9. 09What to check at the final walkthrough

Key takeaway

Compare blown-in cellulose and fibreglass for Ontario attics, including R-value, settling, top-ups, and what to check in an insulation quote.

01Which is better for your attic?

Blown-in cellulose is worth considering when vertical space is tight and the ceiling assembly can carry the specified load. Blown-in fibreglass is worth considering when you have room for a deeper layer and want a lighter installation. The exact trade-off depends on the two products in your quotes. If both can deliver the same thermal resistance with even coverage and suitable prep, either can be a good choice for a dry, vented GTA attic.

A Toronto bungalow with a low roof pitch can run out of room above the exterior walls before it runs out of room in the centre. In a newer Vaughan house with tall roof trusses, a long attic floor and clear eaves, there may be enough room for either product. Take those measurements before treating a general comparison of the materials as a recommendation for your house.

The comparison here is between loose-fill products blown across the flat attic floor. Fibreglass batts, dense-packed wall insulation and insulation applied directly to the underside of a roof are different assemblies. If your quote describes insulation in the rafters or addresses a flat roof, ask how the entire assembly will manage air and moisture.

02How the two materials are made and installed

Cellulose is generally made from processed paper fibre treated for fire resistance and other performance requirements. It looks like small grey flakes or fibres and settles into irregular spaces around framing. For a horizontal application, the installer uses the specified amount of material and follows the product's instructions for the initial depth and the depth after settling.

Loose-fill fibreglass is made from glass fibres and looks soft and fluffy after installation. It comes compressed in bags and the blowing equipment opens up the fibres as it feeds them into the attic. Products differ in colour, fibre structure and density. The applicator still needs to meet the manufacturer's coverage and depth requirements, even if the new layer looks deep from the hatch.

Loose-fill lets the installer work around joists and trusses and cover the tops of framing where space allows. With either material, preparation sets the boundaries for the new layer. Eave baffles preserve the intake path where the design calls for soffit ventilation. A curb holds the fill at the access and suitable barriers maintain clearances at equipment and heat sources. Photograph this work before it disappears beneath the insulation.

03Compare R-value, installed depth and settling

Compare at the same target R-value and on the same area. A quote that says 15 inches of blown-in insulation gives you a depth but leaves out the product and installed density. The product's coverage chart tells you how much area one bag can cover at a given R-value, the minimum required mass or number of bags, and the depth the installer should verify. Read the column headings carefully, especially where an initial and a settled depth are both shown.

For an example near the same target, a published SOPRA-CELLULOSE chart lists R-61 at 16.9 inches settled. The Canadian Owens Corning AttiCat sheet lists R-60 at a minimum installed thickness of 21.5 inches. These are different products at slightly different R-values, and their charts report depth on different bases. The example shows why a depth taken from a general conversion chart is a rough estimate. Ask for the current bag chart for the material that will actually arrive.

Settlement matters if the chart specifies an initial depth above the final depth. The additional depth is part of installing the specified material correctly. Ask the installer to mark the target depth at more than one location and to reconcile the actual bags used with the measured area. A ruler close to the hatch shows one point. The eaves, spaces beyond truss webs and the far end of the roof deserve their own checks.

04Read a bag chart before you compare costs

Start with the measured area of the ceiling below the attic. A two-storey house with 2,000 square feet of living space may have a much smaller attic floor. Work out which ceiling areas are in scope and whether the attic includes split levels or additions. The roof surface area is a different measurement. Ask a contractor to show how they measured if two proposals give noticeably different coverage areas.

For a bare 900-square-foot attic using the AttiCat sheet's R-60 row as an example, multiply the stated minimum of 32.8 bags per 1,000 square feet by 0.9. The result is 29.52 bags, so the estimate rounds up to 30 whole bags, with the chart also requiring at least 21.5 inches installed. That is a check on the material line in the quote. The actual job still needs the correct area, chart, equipment and clearances.

Two products can require very different bag counts because their bag weights and coverage differ. Compare the total installed cost at the same scope, including any air sealing, hatch work, ventilation prep and disposal. If one proposal is cheaper, ask which line items account for the difference. A lower price per bag tells you little until you know the number of bags and the work included around them.

05Consider moisture, ceiling load and the eaves

Start with a dry attic and a clear explanation for any water marks, frost or musty odour. A contractor may need to check for roof leaks, exhaust duct problems and air leakage from the rooms below. Wet material and stained sheathing need assessment before a top-up. Treated cellulose still needs a dry installation, and fibreglass does not protect nearby wood from a leak or recurring condensation.

Weight matters if there is already a deep layer, the ceiling is older or the assembly is unfamiliar. Cellulose commonly adds more mass per square foot than loose-fill fibreglass at a comparable target, but the relevant value comes from the proposed product's coverage chart. If there are signs of sagging, damage, unusual framing or a plaster ceiling of unknown condition, have the assembly checked before choosing a heavier retrofit.

The low point over the exterior wall often decides what is practical. Measuring headroom in the middle tells you very little about the space left where the rafters approach the ceiling joists. Ask for the available insulation depth under the ventilation baffle and how the installer will handle any shallow section. Keeping that air channel open can require a different detail at the edge, even when the rest of the attic takes a uniform layer of loose-fill.

06Can you add cellulose over fibreglass or the reverse?

A top-up over a dry, clean, suitable existing layer can work. Identify what is there, assess its thickness in several places and check for damage or contamination. A fibreglass batt curled up at its edge, compressed insulation under storage boards, or a section stripped during electrical work changes how much thermal resistance you can reasonably credit to the existing material.

Putting a heavier product over a lighter one deserves extra attention because the underlying layer can compress. Ask how the installer will handle the weight and calculate the finished thermal resistance. If you start with a reliable estimate of the existing layer, use the new product's instructions when planning the amount to add. Record the proposed additional R-value and the expected total in the quote. Allow for prep that may require lifting or moving some existing insulation so the crew can seal the ceiling below it.

Removal may be part of the plan if the old fill is wet, contaminated, or blocks access to areas that need repair. Leave material that could be vermiculite undisturbed and seek a qualified asbestos professional before moving anything. For older attics, settle that question before scheduling air sealing, a blower rental, or any work that would disturb the existing material.

07Address air leaks and compare the whole job

Air sealing is a separate part of the attic work. At holes around a plumbing stack, gaps at wall top plates or a poorly fitted hatch, warm air can bypass either loose-fill material. Ask what sealing is feasible before blowing starts, how bathroom exhaust is routed outdoors, and what must stay clear near flues and electrical fixtures. The sealing products and clearances depend on the heat source, equipment and surrounding materials.

Some homeowners also ask about sound, dust and recycled content. Both materials can be part of a sound-control assembly, but a loose-fill upgrade is only one element. Sound also travels through openings and framing. For dust, ask how the crew separates the attic access from finished rooms and what cleanup is included. If recycled content or emissions documentation matters to you, compare the data sheets and published declarations for the named products.

Use the same list for every estimate. Ask for the named material, the measured area, the existing insulation credited, the target R-value, the applicable depth and the minimum amount of product. Have each contractor identify any work on the access hatch, soffit baffles, exhaust and ceiling leaks. With those details, you can see whether a cellulose or fibreglass proposal fits your house and where two prices represent different jobs.

08Match the material to the attic you actually have

In an older East York bungalow with a shallow eave, compare the highest usable depth at the perimeter and how the quote treats the framing above the exterior wall. A shallower loose-fill specification can help in the open area, while the last few inches near the eave may still need a different detail. Ask how the crew will confirm this at the far corners before ordering material. If the proposal assumes the same depth everywhere, confirm those measurements before work begins.

In a two-storey home with tall trusses and a dry existing layer, the choice can come down to the condition of the old insulation and access to the edges. A crew may be able to retain sound material and add a compatible layer, but a platform over a wide area can make coverage complicated. Have the installer show which areas can be covered continuously and how they will keep equipment accessible. Compare any extra platform or carpentry work as its own line item.

A home with a recent roof repair deserves a different timetable. Ask what was repaired, which insulation was wetted, and who will verify that the affected wood and ceiling assembly are ready to close in. A photograph from outside after shingle work will tell you little about the attic materials. Settle the drying and removal scope before picking the fill. If part of the attic must stay empty until the source is confirmed, have that area identified explicitly in the estimate.

For an addition with cathedral ceilings next to an open attic, make two separate scope decisions. The open area may accept a conventional loose-fill blanket. The enclosed roof has different access and drying conditions and may call for a specialist. Ask for the boundary between the two areas to be drawn on the quote so the connection at the transition, which often includes exposed framing or a change in ceiling height, is included in the assessment.

09What to check at the final walkthrough

Ask for photos from before and after the installation, including an eave, the area around the hatch and a representative point far from the opening. If a depth marker is visible in each area, you can see where coverage changes. Ask for the bag count or installation record and compare it with the coverage chart. For a cellulose product with a settling allowance, have the initial installation depth and the expected settled depth recorded separately.

Check that the hatch closes normally and has insulation and a usable gasket. If the attic has a service platform, ask how the insulation was handled around and beneath it and whether equipment remains accessible. A neat job should leave the existing ventilation paths open where designed and preserve the clearances that were agreed in the work scope. Note any unresolved roof or duct repairs separately and agree on who will handle them.

If two proposals still look equally good, decide by the site constraint you can verify. Restricted depth, weight limits or a delicate old ceiling may make the specification decisive. In a straightforward open attic, an even installation with documented preparation and coverage may make the bigger difference. The records also tell the next homeowner or contractor what is in the attic, which can prevent guesswork during future roof, wiring or exhaust work.

Frequently asked questions

Does cellulose have a higher R-value per inch than fibreglass?

Many loose-fill cellulose products reach a given R-value at a shallower depth than some loose-fill fibreglass products. Check the exact bag chart for each product and compare the stated basis for the depth and the minimum amount of material.

Which is cheaper to install in an Ontario attic?

Prices vary with the product, coverage, access, existing insulation and prep needed. Request itemized quotes at the same target R-value and confirm which includes air sealing, hatch work and baffles before comparing the totals.

How many bags do I need for a 1,000-square-foot attic?

The number comes from the bag chart for the exact product and the R-value it needs to add. At a given R-value, read the required bags per 1,000 square feet together with the stated depth. Check whether the existing layer can be credited before making that calculation.

Does blown-in cellulose prevent mice or mould?

For rodents, close the entry points and assess any contamination before insulating. For mould, find and correct the source of moisture, such as a roof leak or a bathroom exhaust problem. Both tasks need attention regardless of which insulation you pick.

Is R-60 always the right attic insulation target?

The appropriate target depends on your attic, the work being done and any requirements that apply to the project. Have the existing assembly assessed before choosing a target or translating it into a depth and bag count.

Sources

  1. 1.Keeping the Heat In: Materials — Natural Resources Canada
  2. 2.Keeping the Heat In: Roofs and attics — Natural Resources Canada
  3. 3.SOPRA-CELLULOSE technical data and attic coverage chart — SOPREMA
  4. 4.AttiCat blown-in fibreglass insulation data sheet — Owens Corning Canada
  5. 5.Asbestos and your health — Health Canada

Written by

Attic Vac Insulation

A licensed and insured attic insulation contractor removing, installing and topping up insulation in homes across Toronto and the GTA, and renting the same 14 HP vacuum we work with.

Related services

Services mentioned in this guide

Attic insulation across the GTA

Attic Vac Insulation technician vacuuming old insulation out of an attic

Still deciding?

Tell us about your attic. We’ll tell you what it actually needs.

Top-up, full removal, spray foam, or just an inspection. A straight recommendation and a written quote, free.

Keep reading

Attic Insulation

8 min read

How Much Does Attic Insulation Cost in Toronto & the GTA? (2026 Guide)

Attic insulation in Toronto and the GTA typically costs $2.00–$4.50 per square foot installed, depending on material and attic condition. See the full 2026 price breakdown by insulation type, typical totals by attic size, and how current rebates change the math.

By Attic Vac Insulation